Abstract:
This study presents an experimental investigation into the industrial foundation piles. The research carried out employed both destructive and non-destructive testing methods to evaluate the concrete compressivestrength and flexural strength capacity of the piles under monotonic loading. The Destructive Test (DT) involves a 28-day cylinder concrete compressive test, while the Non-Destructive Test (NDT) utilizes the Ultrasonic Pulse Velocity (UPV) and Rebound Hammer (RH) tests. The flexural strength test is conductedusing a loading frame, and the results are compared to the GeoPIV-RG, which measures the displacement during the test. The experimental investigations provide insights into the behavior of pile joints when subjected to monotonic load in soft and loose soil. The results indicate a significant difference between the compressive strength obtained from the DT and NDT, with a ratio of 0.64-0.74. Furthermore, the failureoccurred at the joints, rather than the welded area, with the ratio of the initial stiffness of the piles with joints to the monolithic pile being 0.15 for zig-zag welded and 0.30 for circular welded, and reaching an average value of 0.225. According to the GeoPIV-RG result, the displacement is similar to the flexuralstrength test result.